Cpu Components And Functions Pdf Converter
PLCSystemOverview1000x.JPG' alt='Cpu Components And Functions Pdf Converter' title='Cpu Components And Functions Pdf Converter' />TELEDYNE 4. SERIVCE MANUAL Pdf Download. Refrigerated Sampler Service Guide Part 6. Assembly 6. 0 4. Copyright 2. All rights reserved, Teledyne Isco, Inc. Rev. 1. 60 6 i 016 Rev. HT66F002HT66F0025HT66F003HT66F004 CostEffective AD Flash 8Bit MCU with EEPROM. Blackfin 1632bit embedded processors offer software flexibility and scalability for convergent applications multiformat audio, video, voice and image processing. PDF files that contain the Visual Studio 2005 documentation. Cpu Components And Functions Pdf Converter' title='Cpu Components And Functions Pdf Converter' />View and Download Siemens S7200 manual online. SIMATIC Programmable Controller. S7200 Recording Equipment pdf manual download. Search OMRON companys catalogues and technical brochures. Revision F, October 2. Isco 4. 70. 0 Refrigerated Sampler Service Guide Safety Safety Information The Isco 4. Refrigerated Sampler is a definite purpose device, intended for use only with compatible Isco equipment. Except as described in this manual, do not use this product with any other manufacturers equipment, or for any other purpose. Isco 4. 70. 0 Refrigerated Sampler Service Guide Safety General Warnings Before installing, operating, or maintaining this equipment, it is imperative that all hazards and preventive measures are fully understood. While specific hazards may vary according to location and application, take heed in the following general. Isco 4. 70. 0 Refrigerated Sampler Service Guide Safety The equipment and this manual use symbols used to warn of Hazard Symbols hazards. The symbols are explained below. Hazard Symbols Warnings and Cautions The exclamation point within the triangle is a warning sign alerting you of important instructions in the instruments technical reference manual. Isco 4. 70. 0 Refrigerated Sampler Service Guide Safety. Refrigerated Sampler Service Guide Table of Contents Section 1 Introduction and General Guidelines 1. About this Manual. Technical Specifications. CPU Circuit Board Description. Wetted parts. Sampler to RS 2. Self tapping screws reinstallation. Refrigerated Sampler Service Guide Table of Contents 2 6 Opening the pump housing cover and latch. Top cover bushing. Distributor Parts List. Replacement Parts for 4. Refrigerator. Refrigeration System Troubleshooting. Refrigerated Sampler Service Guide Table of Contents. Service Guide Section 1 Introduction and General Guidelines 1. About this Manual This manual contains servicing information for the model 4. The manual contains four sections and three appendices. Section 1, Introduction and General Guidelines, contains safety Teledyne Isco, Inc. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines 1. Technical Table 1 1 contains technical specifications for the 4. Specifications Table 1 1 4. 3D Cad Exercises Pdf. Technical Specifications 1. Size HWD. 4. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines Table 1 1 4. Technical Specifications Continued Speed Approx. RPM, depending on sampling conditions Liquid Presence Detector Non wetted, non conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights. Connection to Other Table 1 2 lists the pin functions of the samplers rear connector, for connection to external devices. Devices Figure 1 1 1. Table 1 2 4. 70. Connector Pin Functions Sampler Pin Signal Name InputOutput ParametersComments 1. VDC Power Output 1. VDC, 1 ampere maximum. General Maintenance The following sections describe general inspection and mainte nance tasks to be performed on the 4. Pump Inspect the pump before each use. Inspections are especially important when pumping large sample volumes over long dis tances or when the sample liquid contains a high percentage of suspended or abrasive solids. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines Figure 1 2 4. Pump Pump Tube Liquid Detector Cover Bulkhead Fitting Latch Tubing Coupler Knob Alignment Notches Pump Housing Alignment Collars Pump Housing Band CAUTION This sampler has a high performance pump. As with all such pumps, it relies upon liquid to cool working components. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines Figure 1 3 Rollers A and guides B on the pump rotor b. Pump Rotor Look for debris buildup on the pump roller or guide surfaces Figure 1 3. Clean when needed Section 1. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines 2. Loosen the Liquid Detector Cover G by unscrewing the large black knob I. Unlatch the Pump Housing Band K. Pull the tube A away from the bulkhead fitting B and disconnect the tubing coupler and suction line. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines Example Resetting the Pump Tube Alarm 1. From the Main Menu screen select CONFIGURE. You can modify the pump tube alarm setting to tailor it to your needs. The factory default setting is. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines For application specific requirements, consult with your labo ratory to establish cleaning or replacement protocols. Figure 1 4 Wetted parts Strainer 3. Bulkhead Fitting 3. CPVCThis zipped file contains two files the 4. Extract these two files. With the 4. 70. 0 turned on, connect it to your computer. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines CAUTION This procedure will cause most programmed entries and accu mulated data stored in the sampler to be lost, and the sampler will revert to factory default settings. If this operation is per formed, it will be necessary for you to reprogram the unit to meet the specifications of your installation. Libro Estadistica Elemental Robert Johnson Pdf'>Libro Estadistica Elemental Robert Johnson Pdf. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines 1. Safety Precautions There are several precautions you should observe before attempting to remove and replace a module WARNING Removing a module exposes you to electrical and mechanical hazards. Always disconnect from AC power before attempting to remove any module. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines 1. Major Assembly Teledyne Isco designed the sampler for easy field replacement of its sub assemblies. This expedites the repair and saves shipping Removal and costs. These sub assembly modules should be replaced by trained Replacement personnel. Section 1 Introduction and General Guidelines Wait for click Figure 1 6 Self tapping screws reinstallation 1. Accessing the Rear 1. Disconnect the 4. AC power. Components WARNING Removing the refrigeration module exposes you to electrical and mechanical hazards. Always disconnect from AC power before exposing the refrigeration module. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines Refrigeration module Insulation Turn module panel out and left Back cover Cover brace Adhesive strip Figure 1 7 Remove back cover and insulation, refrigeration module 1. Closing the Rear Ensure that the control wiring runs through the notches in the plastic refrigerator body. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines Permagum sealant Adhesive strips Power supply cables Figure 1 8 Rear view with module removed Adhesive strips, Permagum sealant, power cables Adhesive Center strip screw Permagum sealant Figure 1 9 Rear view of refrigeration module Adhesive strip, Permagum sealant Replace the refrigeration module, insulation, rear panel, and cover brace, reversing the steps in Section 1. Refrigerated Sampler Service Guide Section 1 Introduction and General Guidelines 1 1. Hidden menu tests are listed in Section 5. Test points For a complete list of 4. Section 4. 2. Test points are also highlighted in red on the CPU schematic in Figure A 5, Appendix A. Refrigerated Sampler Service Guide Section 2 Sample Delivery System 2. Pump Module The pump module is replaceable as a single unit. There have been updates to the 4. See Section 2. 3.